<?xml version="1.0" encoding="UTF-8"?>
<ArticleSet>
  <Article>
    <Journal>
      <PublisherName>KMAN Publication Inc.</PublisherName>
      <JournalTitle>AI and Tech in Behavioral and Social Sciences</JournalTitle>
      <Issn></Issn>
      <Volume></Volume>
      <Issue>In Press</Issue>
      <PubDate PubStatus="epublish">
        <Year>2026</Year>
        <Month>11</Month>
        <Day>14</Day>
      </PubDate>
    </Journal>
    <ArticleTitle>Development and Validation Framework for an Explainable Multimodal Edge AI Wearable System for Academic Stress and Perceived Task Workload in University Students</ArticleTitle>
    <VernacularTitle>Development and Validation Framework for an Explainable Multimodal Edge AI Wearable System for Academic Stress and Perceived Task Workload in University Students</VernacularTitle>
    <FirstPage></FirstPage>
    <LastPage></LastPage>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName></FirstName>
        <LastName></LastName>
        <Affiliation></Affiliation>
      </Author>
    </AuthorList>
    <PublicationType>Journal Article</PublicationType>
    <Abstract>&lt;p&gt;Background: Academic stress and perceived task workload vary during learning activities, but physiological arousal is not specific to either construct. Objective: To describe a prospective protocol for developing and evaluating a multimodal wearable-to-smartphone system using photoplethysmography, electrodermal activity, skin temperature, and accelerometry. Methods: A target cohort of 180 students aged 18–30 years will complete three visits with four counterbalanced academic task blocks per visit. Immediate post-block stress ratings and the unweighted Persian NASA Task Load Index will provide separate block-level reference outcomes. Baseline PSS-10 will support exploratory construct validation only. The primary models will use sensor features aggregated within four-minute blocks, with participant-disjoint nested cross-validation and participant-clustered uncertainty estimates. Post-task self-reports and task identity will be excluded from primary model inputs. Secondary analyses will examine unseen tasks, discordant stress–workload states, missing sensors, calibration, and explanation stability. Illustrative results: The worked example presents 7,776 eligible windows out of 8,640 and fused-model AUROCs of 0.892 for acute stress and 0.873 for high workload. These numerical values illustrate reporting only; they are not participant observations or measured predictive performance. Conclusions: The protocol separates block-level predictive validation from exploratory rolling-window inference. Prospective data collection and independent validation will be needed to determine performance and applicability.&lt;/p&gt;</Abstract>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">academic stress; perceived task workload; wearable computing; explainable artificial intelligence; edge computing; photoplethysmography; electrodermal activity. </Param>
      </Object>
    </ObjectList>
    <ArchiveCopySource DocType="pdf"></ArchiveCopySource>
  </Article>
</ArticleSet>
