Development and Validation Framework for an Explainable Multimodal Edge AI Wearable System for Academic Stress and Perceived Task Workload in University Students
Keywords:
academic stress; perceived task workload; wearable computing; explainable artificial intelligence; edge computing; photoplethysmography; electrodermal activity.Abstract
Background: Academic stress and perceived task workload vary during learning activities, but physiological arousal is not specific to either construct. Objective: To describe a prospective protocol for developing and evaluating a multimodal wearable-to-smartphone system using photoplethysmography, electrodermal activity, skin temperature, and accelerometry. Methods: A target cohort of 180 students aged 18–30 years will complete three visits with four counterbalanced academic task blocks per visit. Immediate post-block stress ratings and the unweighted Persian NASA Task Load Index will provide separate block-level reference outcomes. Baseline PSS-10 will support exploratory construct validation only. The primary models will use sensor features aggregated within four-minute blocks, with participant-disjoint nested cross-validation and participant-clustered uncertainty estimates. Post-task self-reports and task identity will be excluded from primary model inputs. Secondary analyses will examine unseen tasks, discordant stress–workload states, missing sensors, calibration, and explanation stability. Illustrative results: The worked example presents 7,776 eligible windows out of 8,640 and fused-model AUROCs of 0.892 for acute stress and 0.873 for high workload. These numerical values illustrate reporting only; they are not participant observations or measured predictive performance. Conclusions: The protocol separates block-level predictive validation from exploratory rolling-window inference. Prospective data collection and independent validation will be needed to determine performance and applicability.
Downloads
References
Abd-alrazaq, A., Alajlani, M., Ahmad, R., AlSaad, R., Aziz, S., Ahmed, A., Alsahli, M., Damseh, R., & Sheikh, J. (2024). The performance of wearable AI in detecting stress among students: Systematic review and meta-analysis. Journal of Medical Internet Research, 26, e52622. https://doi.org/10.2196/52622
Cohen, S., Kamarck, T., & Mermelstein, R. (1983). A global measure of perceived stress. Journal of Health and Social Behavior, 24(4), 385–396. https://doi.org/10.2307/2136404
Collins, G. S., Moons, K. G. M., Dhiman, P., Riley, R. D., Beam, A. L., Van Calster, B., et al. (2024). TRIPOD+AI statement: Updated guidance for reporting clinical prediction models that use regression or machine learning methods. BMJ, 385, e078378. https://doi.org/10.1136/bmj-2023-078378
Hart, S. G., & Staveland, L. E. (1988). Development of NASA-TLX (Task Load Index): Results of empirical and theoretical research. In P. A. Hancock & N. Meshkati (Eds.), Human mental workload (pp. 139–183). North-Holland. https://doi.org/10.1016/S0166-4115(08)62386-9
Khalili, R., Sirati Nir, M., Ebadi, A., Tavallai, A., & Habibi, M. (2017). Validity and reliability of the Cohen 10-item Perceived Stress Scale in patients with chronic headache: Persian version. Asian Journal of Psychiatry, 26, 136–140. https://doi.org/10.1016/j.ajp.2017.01.010
Lundberg, S. M., & Lee, S.-I. (2017). A unified approach to interpreting model predictions. Advances in Neural Information Processing Systems, 30, 4765–4774. https://proceedings.neurips.cc/paper/2017/hash/8a20a8621978632d76c43dfd28b67767-Abstract.html
Mokhtarinia, H. R., Noshadha, M., Rafat, Z., & Melloh, M. (2026). Translation, cultural adaptation, and psychometric evaluation of the NASA-TLX questionnaire among various occupational groups of Persian speakers. Scientific Reports, 16, Article 32945. https://doi.org/10.1038/s41598-026-63307-3
Moons, K. G. M., Damen, J. A. A., Kaul, T., Hooft, L., Andaur Navarro, C., Dhiman, P., et al. (2025). PROBAST+AI: An updated quality, risk of bias, and applicability assessment tool for prediction models using regression or artificial intelligence methods. BMJ, 388, e082505. https://doi.org/10.1136/bmj-2024-082505
Pataca, A. O., Zdravevski, E., Coelho, P. J., Garcia, N. M., Deryuck, M., Albuquerque, C., & Pires, I. M. (2025). Use of machine learning for predicting stress episodes based on wearable sensor data: A systematic review. Computers in Biology and Medicine, 198(Part A), 111166. https://doi.org/10.1016/j.compbiomed.2025.111166
Pinge, A., Gad, V., Jaisighani, D., Ghosh, S., & Sen, S. (2024). Detection and monitoring of stress using wearables: A systematic review. Frontiers in Computer Science, 6, 1478851. https://doi.org/10.3389/fcomp.2024.1478851
Roberti, J. W., Harrington, L. N., & Storch, E. A. (2006). Further psychometric support for the 10-item version of the Perceived Stress Scale. Journal of College Counseling, 9(2), 135–147. https://doi.org/10.1002/j.2161-1882.2006.tb00100.x
Schmidt, P., Reiss, A., Duerichen, R., Marberger, C., & Van Laerhoven, K. (2018). Introducing WESAD, a multimodal dataset for wearable stress and affect detection. Proceedings of the 20th ACM International Conference on Multimodal Interaction (pp. 400–408). Association for Computing Machinery. https://doi.org/10.1145/3242969.3242985
Sharif-Nia, H., Froelicher, E. S., Hoseinzadeh, E., Kaveh, O., Fatehi, R., & Nowrozi, P. (2024). Assessing the validity and reliability of the 10-item Persian version of the perceived stress scale in post-surgery patients. Frontiers in Psychiatry, 15, 1402122. https://doi.org/10.3389/fpsyt.2024.1402122
Yu, J., & Wan, J. (2026). AI-supported cognitive load detection: Experimental insights using wearable workload and stress data for enhanced well-being interventions. Scientific Reports, 16, Article 36348. https://doi.org/10.1038/s41598-026-64103-9